LED Neon Flex vs LED Strip: Which for Signage
LED neon flex and bare LED strips differ in diffusion, bend radius and durability. Compare both for signage and learn which suits outlines and wash lighting.
GMH Lighting · Published September 8, 2026 · Updated October 14, 2026 · 5 min read
LED neon flex is a strip of LEDs sealed inside a silicone or PVC jacket that diffuses light into a continuous line, while a bare LED strip is an exposed PCB with discrete diodes. Neon flex bends to a tighter radius of roughly 20–30 mm and gives smoother, dot-free light. Bare strips are cheaper and better for hidden wash lighting on 12V or 24V signs.
Key points
- Neon flex diffuses LEDs into a continuous line; bare strips show individual dots.
- Neon flex bends to roughly 20–30 mm radius; most bare strips need 50 mm or more.
- Neon flex is typically IP65 or IP67; bare strips may be only IP20 unless coated.
- Bare strips cost less per metre and suit hidden wash lighting on 12V or 24V signs.
Two different products
Although both are flexible linear lights, LED neon flex and bare LED strip solve different problems. A bare strip is a flexible printed circuit board with individual diodes exposed on its surface. Neon flex takes a similar strip and seals it inside a silicone or PVC jacket that spreads the light into a smooth, continuous line.
The choice comes down to whether the light will be seen directly. If it will, the even line of neon flex usually wins. If it will be hidden behind a diffuser or an edge, a bare strip is more economical.
| Feature | LED neon flex | Bare LED strip |
|---|---|---|
| Light appearance | Continuous, dot-free line | Visible individual diodes |
| Construction | LEDs sealed in silicone/PVC | Exposed LEDs on PCB |
| Minimum bend radius | Roughly 20–30 mm | About 50 mm or more |
| Typical rating | IP65 / IP67 | IP20 unless coated |
| Relative cost per metre | Higher | Lower |
Light quality and diffusion
The main reason to choose neon flex is uniformity. The silicone jacket acts as a diffuser, blending the light from adjacent diodes so the eye sees one steady line. A bare strip, by contrast, shows distinct points of light unless it is mounted behind a deep enough diffuser.
That difference matters for visible signage. A logo outline or a letter stroke made with bare strip can look like a row of dots up close. Neon flex hides the individual sources and reads as a clean stroke, which is closer to the look of traditional glass neon.
The trade-off is brightness. The jacket absorbs some light — commonly around 15–30% — so a neon flex of a given wattage appears dimmer than a bare strip of the same wattage. Most sign designers accept this because evenness is more valuable than peak brightness.
Bending and shaping
Sign outlines often require tight curves. Neon flex is built for this and typically bends to a radius of roughly 20–30 mm without damaging the internal strip. Bare strips are stiffer in comparison and generally need a radius of about 50 mm or more; folding one too sharply can crack the board or break a solder joint.
For very sharp corners, neither product should be folded at a right angle. Use purpose-made corner connectors and join straight segments instead. This keeps the light continuous and preserves the ingress rating.
Weather protection
Neon flex is normally supplied as IP65 or IP67, making it a straightforward choice for outdoor signs. Bare strips are often IP20 — protected against solid objects but not water — unless a coated version is specified. Adding a coating reduces heat dissipation, as discussed in the IP65 vs IP67 guide.
| Application | Recommended product | Reason |
|---|---|---|
| Shop logo outline | Neon flex, IP65 | Smooth line, weather resistant |
| Vehicle lettering | Neon flex, IP67 | Vibration and moisture |
| Hidden cove lighting | Bare strip, IP20 | Cheaper, cooler running |
| Lightbox backlighting | Bare strip or modules | Even wash behind diffuser |
Compare the available LED strip and neon flex formats when planning a sign.
Voltage and power
Both products are commonly available in 12V and 24V versions. As with all LED signage, the voltage must match the power supply. Long runs at 12V draw higher current and lose more voltage along the cable, so 24V is often preferable for large installations. Size the supply with 20% headroom.
Common mistakes
- Using bare strip for a visible outline. The dots will show.
- Folding a strip around a tight corner. Use connectors instead.
- Assuming the strip rating covers the connectors. Seal every joint.
- Ignoring the jacket’s light loss. Allow for 15–30% when estimating brightness.
Estimating running cost and lifetime
Power draw is a practical difference between the two products. Because neon flex loses 15–30% of its light in the jacket, it often needs more input power to reach the same visible brightness as a bare strip. Over a long run, that difference affects both the electricity bill and the size of the power supply.
A typical calculation works like this: a 5 m run drawing 10 W per metre consumes 50W. With 20% supply headroom, choose a 60–100W unit at the matching 12V or 24V. Run the same installation for 10 hours a day and it uses about 0.5 kWh per day.
Heat also affects life. A bare strip mounted on an aluminium profile stays cooler than the same strip sealed inside neon flex, and cooler LEDs maintain output longer. Where the sign is visible and appearance matters, the even line of neon flex usually justifies the extra cost. Where the light is hidden behind a diffuser, a bare strip on a profile is the more efficient choice.
Both products can be dimmed, but confirm that the chosen controller is compatible before ordering. A mismatched dimmer can cause flicker at low output.
Scope and limits
This page does not cover glass neon tube fabrication, transformers or the high-voltage safety practices associated with neon. It does not address programmable or addressable strips with built-in controllers, which have different wiring requirements. It also excludes aluminium profile systems and mounting channels, which affect heat and appearance.
Related reading
- IP67 vs IP65 LED strip: what is the real difference
- Color temperature and CRI for advertising signage
- What is a LED channel letter?
This article describes general manufacturing practice for machined and fabricated components. It is not a substitute for a drawing-specific engineering review — tolerances, material selection and process capability depend on the individual part.